The main pipe, main pipe, and branch pipe had different definition and functions in the water supply system. The following conclusions:
The main pipe referred to the pipe section from the indoor main valve (or water meter) to the water supply standpipe. It was usually in the form of a standpipe, responsible for guiding water from the water source to various locations in the building. The main water supply line was usually the main water supply line in the system and could span multiple floors.
The main pipe referred to the pipe section from the water source to the most unfavorable point. The most unfavorable point could be the farthest water distribution point or the highest water distribution point. The main pipe was usually in the form of a vertical pipe or a horizontal pipe, because it must have small pipes that were divided from other pipes. These small pipes were branch pipes. The function of the main pipe was to connect the pipe section of the household pipe and the branch pipe to carry out up and down transportation.
The branch pipe was a water distribution pipe on the same floor, starting from the main pipe and ending at the water distribution valve of the faucet or sanitary ware. The branch pipe was usually a horizontal pipe that connected to sanitary ware or other water points.
In summary, the main pipe, the main pipe, and the branch pipe have different meanings and functions in the water supply system. The main pipe was the main water supply line, the main pipe was the pipe section that connected the household pipe and the branch pipe to transport water up and down, and the branch pipe was the water distribution pipe on the same floor.
There were several ways to repair the leaking pipe in the bathroom. First of all, the original ceramic tiles could be removed and the base surface could be treated to remove the problem of water leakage in the waterproof layer. Then, he used the mud to level the ground and re-waterproof it. Finally, he laid the tiles. This would solve the problem of the bathroom leaking. In addition, if it was a problem with the water pipes, he could consider changing the hidden pipes to open pipes. In addition, if the bathroom is damp, the ceiling can be replaced with a waterproof PVP buckle to effectively prevent moisture and prevent steam from entering the hidden pipe and causing water leakage. To determine which side was leaking, one could observe the color of the floor tiles to determine if there was water. If there was already a leak, it was recommended to contact the property management of the community for repair. Don't deal with it yourself to avoid problems. During maintenance, it was necessary to find the leaking point. It could be located by professionals using ultrasonic audiometer and thermal imaging detector equipment, and then repaired and sealed. After the repairs were completed, they needed to wait for the walls and tiles to dry before they were restored to their original state. The cost of maintenance varied from city to city, generally around 1,000 - 3,000 yuan.
The method to obtain the Poison God in the Legend of the Sword and Fairy 2 was as follows: First, in April, you needed to explore the Fairy Island through Anu and obtain the Bee Emperor. Then, in September, he would explore the Miao territory through Anu and obtain the Mother of Gu. Finally, at the end of the month, the plot of obtaining the Poison God alone would be triggered. The specific game strategy can be found in the relevant articles.
The difference between the horizontal branch drainage pipe and the horizontal main drainage pipe was their function and connection method. The horizontal branch drainage pipe was a horizontal pipe section connected to the sanitary ware, usually connected vertically or diagonally to the main pipe. It was used to distribute water to different zones or floors and supply specific faucet or equipment through the horizontal branch pipe. The horizontal main pipe was the main pipe in the system, also known as the main pipe. It was usually in the basement or buried. It went from the water source to the most unfavorable point. The most unfavorable point was usually the farthest water distribution point or the water distribution point at the elevation. Therefore, the difference between the horizontal branch pipe and the horizontal main pipe was their function and location.
The length of the Genshin story is hard to define precisely. It's constantly growing as the game developers introduce new quests, characters, and plotlines. But it's already quite substantial.
When the buried water pipe leaked, the water source had to be disconnected first and the leaking port had to be found. If the leakage was not serious, it could be repaired with professional mixed glue. As for the leakage of the buried PPR water pipe, it was necessary to dig and re-welding the pipe. In the case of leakage from the buried water pipe in the kitchen, the water supply valve should be closed immediately to prevent further damage. If the water pipe in the bathroom was leaking, he might need to knock open the ground and rebuild the pipe. As for the leakage of the water pipes buried in the outer wall and the wall, it is recommended to ask the property management or professional company to repair it. As for the leakage at the mouth of the pipe or the root of the pipe, the front or back method could be used to treat the leakage. As for who was responsible for the leakage of the water pipes buried under the tiles in the house, the owner or the upstairs resident might be responsible according to the specific situation.
Spiral drainage pipe was a kind of pipe used in building drainage system, which had some characteristics and advantages. Spiral drainage pipe has the following characteristics:
1. Reduce noise: The design of the spiral drainage pipe can effectively reduce the noise pollution caused by drainage. The measured results showed that compared with the traditional cast iron drainage pipe, the noise of the spiral drainage pipe was about 2 to 4 decibels lower, and it had a silencing effect.
2. To prevent the damage of the floor drain seal: The spiral structure inside the spiral drainage pipe can reduce the pressure fluctuation in the pipe, avoid the damage of the water seal caused by the negative pressure of the upper user and the positive pressure of the bottom user, and improve the stability of the drainage system.
3. Increase drainage efficiency: The internal spiral structure of the spiral drainage pipe increases the friction resistance of the water flow, preventing the water flow from blocking the pipe due to inertia, improving drainage efficiency and reducing the occurrence of blockage accidents.
4. [Double silencing effect: Hollow wall spiral drainage pipe is a special structure of spiral drainage pipe. It has a double-layer structure and honeycomb-shaped holes, which can further isolate noise and have a better silencing effect.]
In general, the spiral drainage pipe had the advantages of reducing noise, preventing the damage of the floor drain seal, and improving drainage efficiency. They are commonly used in the drainage system of buildings, especially for the drainage of single standpipes in high-rise buildings.